67 research outputs found

    A Review of Wearable Sensor Systems to Monitor Plantar Loading in the Assessment of Diabetic Foot Ulcers

    Get PDF
    Diabetes is highly prevalent throughout the world and imposes a high economic cost on countries at all income levels. Foot ulceration is one devastating consequence of diabetes, which can lead to amputation and mortality. Clinical assessment of diabetic foot ulcer (DFU) is currently subjective and limited, impeding effective diagnosis, treatment and prevention. Studies have shown that pressure and shear stress at the plantar surface of the foot plays an important role in the development of DFUs. Quantification of these could provide an improved means of assessment of the risk of developing DFUs. However, commercially-available sensing technology can only measure plantar pressures, neglecting shear stresses and thus limiting their clinical utility. Research into new sensor systems which can measure both plantar pressure and shear stresses are thus critical. Our aim in this paper is to provide the reader with an overview of recent advances in plantar pressure and stress sensing and offer insights into future needs in this critical area of healthcare. Firstly, we use current clinical understanding as the basis to define requirements for wearable sensor systems capable of assessing DFU. Secondly, we review the fundamental sensing technologies employed in this field and investigate the capabilities of the resultant wearable systems, including both commercial and research-grade equipment. Finally, we discuss research trends, ongoing challenges and future opportunities for improved sensing technologies to monitor plantar loading in the diabetic foot

    An inductive force sensor for in-shoe plantar normal and shear load measurement

    Get PDF
    Diabetic foot ulcers (DFUs) are a severe global public health issue. Plantar normal and shear load are believed to play an important role in the development of foot ulcers and could be a valuable indicator to improve assessment of DFUs. However, despite their promise, plantar load measurements currently have limited clinical application, primarily due to the lack of reliable measurement techniques particularly for shear load measurements. In this paper we report on the design and evaluation of a novel tri-axis force sensor to measure both normal and shear load on the foot’s plantar surface simultaneously. The sensor consists of a group of inductive sensing coils above which a conductive target is placed on a hyperelastic elastomer. Movement of the target under load affects the coil inductances which are measured and digitized by an embedded system. Using a computational finite element model, we investigated the influence of sensing coil form and configuration on sensor performance. A sensor configured with four-square coils and maximal turns provided the best performance for plantar load measurements. A prototype was fabricated and calibrated using a neural network to map the non-linear relationship between the sensor output and the applied tri-axis load. Experimental evaluation indicates that the tri-axis sensor can effectively detect shear load of �16 N and normal load up to 105 N (RMS errors: 1.05 N and 1.73 N respectively) with a high performance. Overall, this sensor provides a promising basis for plantar normal and shear load measurement which are crucial for improved assessment of DFU

    Survey of ultrasound practice amongst podiatrists in the UK

    Get PDF
    Background: Ultrasound in podiatry practice encompasses musculoskeletal ultrasound imaging, vascular hand-held Doppler ultrasound and therapeutic ultrasound. Sonography practice is not regulated by the Health and Care Professions Council (HCPC), with no requirement to hold a formal qualification. The College of Podiatry does not currently define ultrasound training and competencies. This study aimed to determine the current use of ultrasound, training received and mentorship received and/or provided by podiatrists using ultrasound. Methods: A quantitative study utilising a cross-sectional, on-line, single-event survey was undertaken within the UK. Results: Completed surveys were received from 284 podiatrists; 173 (70%) use ultrasound as part of their general practice, 139 (49%) for musculoskeletal problems, 131 (46%) for vascular assessment and 39 (14%) to support their surgical practice. Almost a quarter (n=62) worked for more than one organisation; 202 (71%) were employed by the NHS and/or private sector (n=118, 41%). Nearly all (93%) respondents report using a hand-held vascular Doppler in their daily practice; 216 (82%) to support decisions regarding treatment options, 102 (39%) to provide diagnostic reports for other health professionals, and 34 (13%) to guide nerve blocks. Ultrasound imaging was used by 104 (37%) respondents primarily to aid clinical decision making (n=81) and guide interventions (steroid injections n=67; nerve blocks n=39). Ninety-three percent stated they use ultrasound imaging to treat their own patients, while others scan at the request of other podiatrists (n=28) or health professionals (n=18). Few use ultrasound imaging for research (n=7) or education (n=2). Only 32 (11%) respondents (n=20 private sector) use therapeutic ultrasound to treat patients presenting with musculoskeletal complaints, namely tendon pathologies. Few respondents (18%) had completed formal post-graduate CASE (Consortium for the Accreditation of Sonographic Education) accredited ultrasound courses. Forty (14%) respondents receive ultrasound mentorship; the majority from fellow podiatrists (n=17) or medical colleagues (n=15). Over half (n=127) who do not have ultrasound mentorship indicated they would like a mentor predominantly for ultrasound imaging. Fifty-five (19%) report they currently provide ultrasound mentorship for others. Conclusions: Understanding the scope of ultrasound practice, the training undertaken and the requirements for mentorship will underpin the development of competencies and recommendations defined by the College of Podiatry to support professional development and ensure safe practice.</p

    STrain Analysis and Mapping of the Plantar Surface (STAMPS): A novel technique of plantar load analysis during gait

    Get PDF
    Diabetic foot ulceration is driven by peripheral neuropathy, resulting in abnormal foot biomechanics and elevated plantar load. Plantar load comprises normal pressure and tangential shear stress. Currently, there are no in-shoe devices measuring both components of plantar load. The STAMPS (STrain Analysis and Mapping of the Plantar Surface) system was developed to address this and utilises digital image correlation (DIC) to determine the strain sustained by a plastically deformable insole, providing an assessment of plantar load at the foot-surface interface during gait. STAMPS was developed as a multi-layered insole, comprising a deformable mid-layer, onto which a stochastic speckle pattern film is applied. A custom-built imaging platform is used to obtain high resolution pre- and post-walking images. Images are imported into commercially available DIC software (GOM Correlate, 2020) to obtain pointwise strain data. The strain and displacement data are exported and post-processed with custom analysis routines (MATLAB, Mathworks Inc.), to obtain the resultant global and regional peak strain (SMAG), antero-posterior strain (SAP) and medio-lateral strain (SML). To validate the core technique an experimental test process used a Universal Mechanical Tester (UMT) system (UMT TriboLab, Bruker) to apply controlled vertical and tangential load regimes to the proposed multi-layer insole. A pilot study was then conducted to assess the efficacy of using the STAMPS system to measure in-shoe plantar strain in three healthy participants. Each participant walked 10 steps on the STAMPS insole using a standardised shoe. They also walked 10 m in the same shoe using a plantar pressure measurement insole (Novel Pedar®) to record peak plantar pressure (PPP) as a gold-standard comparator. The results of the experimental validation tests show that with increased normal force, at a constant shear distance, SMAG increased in a linear fashion. Furthermore, they showed that with increased shear distance, at a constant force, SMAG increased. The results of the pilot study found participant 1 demonstrated greatest SMAG in the region toes 3–5 (15.31%). The highest mean SMAG for participant 2 was at the hallux (29.31%). Participant 3 exhibited highest strain in the regions of the first and second metatarsal heads (58.85% and 41.62% respectively). Increased PPP was strongly associated with increased SMAG with a Spearman’s correlation coefficient 0.673 (p < 0.0001). This study has demonstrated the efficacy of a novel method to assess plantar load across the plantar surface of the foot. Experimental testing validated the sensitivity of the method to both normal pressure and tangential shear stress. This technique was successfully incorporated into the STAMPS insole to reliably measure and quantify the cumulative degree of strain sustained by a plastically deformable insole during a period of gait, which can be used to infer plantar loading patterns. Future work will explore how these measures relate to different pathologies, such as regions at risk of diabetic foot ulceration

    Decline in health-related quality of life and foot and ankle patient reported outcomes measures in patients with haemophilia and ankle haemarthropathy

    Get PDF
    Background Haemophilia is an X-linked recessive genetic disorder characterised by bleeding within soft tissue and joints. The ankle is disproportionally affected by haemarthropathy when compared to the elbows and knees; reported as the most affected joints in patients with haemophilia. Despite advances in treatment, patients still report ongoing pain and disability, however, the impact has not been evaluated, nor has the effect on health-related quality of life (HRQoL) or foot and ankle patient-reported outcome measures (PROMs). The primary aim of this study was to establish the impact of ankle haemarthropathy in patients with severe and moderate haemophilia A and B. Secondly to identify the clinical outcomes associated with a decline in HRQoL and foot and ankle PROMs. Methods A cross-sectional multi-centre questionnaire study was conducted across 18 haemophilia centres in England, Scotland and Wales with a recruitment target of 245 participants. The HAEMO-QoL-A and Manchester-Oxford Foot Questionnaire (MOXFQ) (foot and ankle) with total and domain scores measured impact on HRQOL and foot and ankle outcomes. Demographics, clinical characteristics, ankle haemophilia joint health scores, multi-joint haemarthropathy and Numerical Pain Rating Scales (NPRS) of “ankle pain over the past six months” were collected as a measure of chronic ankle pain. Results A total of 243 of 250 participants provided complete data. HAEMO-QoL-A and MOXFQ (foot and ankle) total and index scores indicated worse HRQoL with total scores ranging from a mean of 35.3 to 35.8 (100 best-health) and 50.5 to 45.8 (0 best-health) respectively. NPRS (mean (SD)) ranged from 5.0 (2.6) to 5.5 (2.5), with median (IQR) ankle haemophilia joint health score of 4.5 (1 to 12.5) to 6.0 (3.0 to 10.0) indicating moderate to severe levels of ankle haemarthropathy. Ankle NPRS over six months and inhibitor status were associated with decline in outcome. Conclusions HRQoL and foot and ankle PROMs were poor in participants with moderate to severe levels of ankle haemarthropathy. Pain was a major driver for decline in HRQoL and foot and ankle PROMs and use of NPRS has the potential to predict worsening HRQoL and PROMs at the ankle and other affected joints

    Plantar plate pathology is associated with erosive disease in the painful forefoot of patients with rheumatoid arthritis

    Get PDF
    Background: Disease-related foot pathology is recognised to have a significant impact on mobility and functional capacity in the majority of patients with rheumatoid arthritis (RA). The forefoot is widely affected and the metatarsophalangeal (MTP) joints are the most common site of symptoms. The plantar plates are the fibrocartilaginous distal attachments of the plantar fascia inserting into the five proximal phalanges. Together with the transverse metatarsal ligament they prevent splaying of the forefoot and subluxation of the MTP joints. Damage to the plantar plates is a plausible mechanism therefore, through which the forefoot presentation, commonly described as ‘walking on pebbles’, may develop in patients with RA. The aims of this study were to investigate the relationship between plantar plate pathology and clinical, biomechanical and plain radiography findings in the painful forefoot of patients with RA. Secondly, to compare plantar plate pathology at the symptomatic lesser (2nd-5th) MTP joints in patients with RA, with a group of healthy age and gender matched control subjects without foot pain. Methods: In 41 patients with RA and ten control subjects the forefoot was imaged using 3T MRI. Intermediate weighted fat-suppressed sagittal and short axis sequences were acquired through the lesser MTP joints. Images were read prospectively by two radiologists and consensus reached. Plantar plate pathology in patients with RA was compared with control subjects. Multivariable multilevel modelling was used to assess the association between plantar plate pathology and the clinical, biomechanical and plain radiography findings. Results: There were significant differences between control subjects and patients with RA in the presence of plantar plate pathology at the lesser MTP joints. No substantive or statistically significant associations were found between plantar plate pathology and clinical and biomechanical findings. The presence of plantar plate pathology was independently associated with an increase in the odds of erosion (OR = 52.50 [8.38–326.97], p < 0.001). Conclusion: The distribution of plantar plate pathology at the lesser MTP joints in healthy control subjects differs to that seen in patients with RA who have the consequence of inflammatory disease in the forefoot. Longitudinal follow-up is required to determine the mechanism and presentation of plantar plate pathology in the painful forefoot of patients with RA

    A systematic review and narrative synthesis of footwear and orthotic devices used in the management of ankle haemarthrosis and haemarthropathy in haemophilia

    Get PDF
    Introduction Haemarthrosis is a clinical feature of haemophilia leading to haemarthropathy. The ankle joint is most commonly affected, resulting in significant pain, disability and a reduction in health-related quality of life. Footwear and orthotic devices are effective in other diseases that affect the foot and ankle, such as rheumatoid arthritis, but little is known about their effect in haemophilia. Aims To review the efficacy and effectiveness of footwear and orthotic devices in the management of ankle joint haemarthrosis and haemarthropathy in haemophilia. Methods A systematic literature review was conducted. Two review authors independently screened studies for inclusion and appraised methodological quality using Joanna Briggs Institute Critical Appraisal checklists. A narrative analysis was undertaken. Results Ten studies involving 271 male participants were eligible for inclusion. All studies were quasi-experimental; three employed a within-subject design. Two studies included an independent comparison or control group. A range of footwear and orthotic devices were investigated. Limited evidence from non-randomised studies suggested that footwear and orthotic devices improve the number of ankle joint bleeding episodes, gait parameters, and patient-reported pain. Conclusion This review demonstrates a lack of robust evidence regarding the efficacy and effectiveness of footwear and orthotic devices in the management of ankle joint haemarthrosis and haemarthropathy in haemophilia. Methodological heterogeneities and limitations with the study designs, small sample sizes and limited follow-up of participants exist. Future studies utilising randomised designs, larger sample sizes, long-term follow-up, and validated patient-reported outcome measures are needed to inform the clinical management of ankle joint haemarthrosis and haemarthropathy

    A Portable Insole System to Simultaneously Measure Plantar Pressure and Shear Stress

    Get PDF
    Objective: This work aims to develop an integrated in-shoe measurement system to fully record plantar loading, including both pressure and shear stresses, across the full contact surface. These data are vital to help understand and prevent the development of complex conditions such as Diabetic Foot Ulcers (DFUs), a worldwide healthcare challenge. Currently no systems exist to reliably record these data. Methods: In this paper we report development of the SLIPS ('Shear Load Inductive Plantar Sensing') system which integrates 64 tri-axial force sensors into a flexible insole to measure plantar loading. SLIPS translates our multi-axis inductive load sensing technology into a full sensory array embedded within an insole and complete with communication and power bus. A pilot study evaluates the system in three healthy participants during walking. Results: Testing shows that the SLIPS system is well tolerated by participants and can operate under dynamic gait loading regimes. The pilot study reveals the complex nature of plantar loading. Regions of peak pressure loading align with anatomical landmarks and shear loading forms a significant component of the overall load. Notably, regions of peak shear and pressure are not necessarily collocated or present in unison. Conclusion: This work highlights the need for in-shoe plantar measurement systems like SLIPS capable of mapping both pressure and shear load, and their use to improve understanding of how these factors relate to clinical conditions like DFU. Significance: SLIPS represents the first in-shoe measurement system capable of measuring both pressure and shear across the whole plantar surface in unison

    "I could have a proper ankle" - a qualitative study of patients' perceptions of total ankle replacement and ankle fusion surgery.

    Get PDF
    BACKGROUND: End-stage ankle osteoarthritis typically causes severe pain and impaired function. Surgical treatment involves total ankle replacement (TAR) or ankle fusion. Definitive evidence about which procedure is optimal is lacking. No previous studies have thoroughly explored patients' experiences across the entire TAR/ankle fusion pathway. This study aimed to address this gap by exploring perceptions of surgery, education, rehabilitation and outcomes among patients who had undergone TAR or ankle fusion. METHODS: Seven participants were purposively selected from an orthopaedic centre in northern England (3 females, 4 males). Participants had undergone primary TAR without revision (n = 2), TAR requiring revision (n = 3) or ankle fusion (n = 2). Each participant completed a single semi-structured interview. Interviews were digitally recorded, transcribed verbatim and analysed thematically. RESULTS: Three themes, each with two subthemes, were identified: decision-making (seeking help; surgical options), perceptions of support (information/education; clinical support) and impact on the individual (personal circumstances and beliefs; post-operative outcomes). Pain affecting participants' valued activities was key to their decision to seek help. Participants' decision between TAR and ankle fusion was influenced by multiple factors. Concerns regarding the lack of joint flexibility following fusion were highlighted, with some participants perceiving TAR as a "proper ankle" that would enable them to avoid limping. Participants obtained information from various sources, with most feeling that the education from their care team was inadequate. Participants' individual circumstances and beliefs influenced their decision-making and perceptions of their post-operative outcomes. Finally, whilst most participants were pleased with their outcomes, some experienced substantial ongoing problems such as difficulty walking and chronic pain. CONCLUSIONS: This study demonstrates the importance of providing adequate education about TAR and ankle fusion to enable patients to make informed decisions. Most participants felt that the education and clinical support they received did not fully meet their needs. Participants' personal circumstances and beliefs had a strong influence on their decision-making and perceptions of their post-operative outcomes, highlighting the need to personally tailor education and clinical support. Future work with a larger sample of patients and other key stakeholders is required to develop consensus-based guidelines on pre- and post-operative support for patients undergoing TAR/ankle fusion
    corecore